Illuminance Converter
Converts lux and foot-candles on this page.
About this tool
The value is converted through a single base unit for that dimension. Labels name the system when US and UK differ.
Affine units share one base. Temperature-style offsets are not used in this set.
How to use it
- Open this page and provide the input it asks for.
- Set the options that are visible, then use Convert.
- Read the result in the panel. Copy it or download it when a file is offered. The input stays in this browser.
Limitations
- Affine units share one base. Temperature-style offsets are not used in this set.
Foot-candles expanded by the stored lux factor
Lux at rest, foot-candles with a long multiplier
Illuminance has two rows. Lux stores 1. Foot-candle stores 10.76391041671. One foot-candle is therefore 10.76391041671 lux, the factor copied in full, not a rounded 10.76. The candela is the SI base unit in the light family, and lux is the illuminance unit this table treats as the hub. The foot-candle row does not send you off to rescale a length into feet and then invent a lighting unit. The multiplier is already stored. Offsets are 0. Twice the illuminance is twice the number. A dimmer setting is not a unit, and the page will not map a percentage slider onto lux.
One foot-candle, then a brighter room
Type 1 as foot-candles and ask for lux. The result is 10.76391041671. Twenty foot-candles, a modest indoor target in some lighting notes, are 215.2782083342 lux. Fifty are 538.1955208355 lux. If a specification is already in lux, leave it on the lux row. Dividing a lux figure by 10.76391041671 recovers foot-candles. Using 10.764 instead shifts the result in the last digits the table is capable of keeping. Office drawings and horticultural notes sometimes mix the two names in one paragraph. Convert with the stored factor before you compare them. A foot-candle is not a foot from the length list and not a candle as a mass or a cost.
Lumens and exposure are other quantities
Luminous flux in lumens is not a row. A lamp’s lumen rating becomes an illuminance only after you account for area and geometry, which this menu does not do. It will not divide lumens by square metres, even though that story is how lux is taught. Bring the illuminance you have. Photographic exposure, candela per square metre, and nits are absent. Distance from the lamp changes the reading in the room and does not change the factor 10.76391041671. A negative illuminance scales and is not a physical light level. Zero stays darkness in the story and zero in the product.
Privacy
Your input is processed in your browser and is not uploaded to UtilChain. File names, text, and results are not sent to analytics.

