Color Blindness Simulator

Simulate protanopia, deuteranopia, or tritanopia for one color.

Use this tool

Result

The result appears in this panel after you run the tool.

About this tool

The selected matrix is applied to the RGB color you entered. The result is another color you can compare with the original.

Photograph simulation belongs on an image tool. This page never reads a file.

How to use it

  1. Enter a color.
  2. Choose protanopia, deuteranopia, or tritanopia.
  3. Simulate. The page shows the transformed color, not a filtered photograph.

Limitations

Encoded channels through a Machado matrix

The multiply that actually runs

The input is one hex color. The mode is protanopia, deuteranopia, or tritanopia, and it defaults to deuteranopia. Each mode has a fixed 3 by 3 matrix, the Machado 2009 figures stored for sRGB. The page divides red, green, and blue by 255, multiplies that triple by the matrix, multiplies by 255 again, and clamps each channel into 0 through 255. There is no separate linearization step before the multiply and no re-encoding step after it. The matrix is applied to the encoded channel numbers. The result is written as hex, with a line that names the mode and states that the run was a single color.

Both swatches are shown: the original, and the transformed color. The original hex is normalized to six digits before the multiply, so a three-digit input and its expanded form take the same path. An unknown mode is an error. There is no control for anomalous trichromacy, for a severity percentage, or for a custom matrix. Protanomaly is not a lighter version of the protanopia row. If that is what you needed, this page does not offer it.

A single swatch is not a photograph

Only the one color is transformed. An uploaded picture is not recolored, and a gradient string is not walked stop by stop. Two colors that remain distinct after the matrix can still collapse in a real scene where they sit side by side with texture. The model does not know that context. It also does not know the viewer’s diagnosis. The output is a simulation of a color, not a medical result and not a certification.

Display calibration is not part of the matrix. The hex is assumed to be sRGB on a reference display. A wide-gamut screen or a dim room can change what you see without changing the hex the page prints. Printer plates are not simulated. If you need a numeric distance between the original and the simulation, copy both hex values into the delta-E page. The CIE76 figure there is a Lab distance. It is not a prediction that a particular person will or will not tell the colors apart. Use this simulator to see the transformed swatch. Use contrast separately if the question is text on a background.

Privacy